HEATING COOLING MACHINE AVAILABLE FOR HIRE
ATEX, FLP MODELS AVAILABLE

Select your Model

Please filter by temperature based on your specifications

SUNDI-320/420W/430W

Download PDF
ModelSUNDI-320 SUNDI-420W SUNDI-430W
Heating Power (kW)223
Cooling capacity at 180oC (kW)1.51.83
Cooling capacity at 50oC (kW)1.51.83
Cooling capacity at 0oC (kW)1.51.83
Cooling capacity at -5oC (kW)0.91.22
Cooling capacity at -20oC (kW)0.611.5
Cooling capacity at -35oC (kW)00.30.5
Circulation Pump
Max Flow (l/min)
000
Circulation Pump
Max Pressure (bar)
000
Connection sizeG1/2 G1/2 G1/2
Water-cooled type
W (AT 20℃)
450L/H 1.5bar~4bar550L/H 1.5bar~4bar
Dimension cm400*600*870 400*600*870
Dimension(W) cm//
Isolated ex-proof
size cm
700*750*1215 700*750*1215
Positive Pressure (W) cm///
Weight kg55kg55kg85kg
Power MAX
380V 50HZ
AC 220V 50HZ 2.9kW(max) AC 220V 50HZ 3.3kW(max) AC380V 50HZ 4.5kW(max)
Optional size
  • Temp Range
  • -30oC~180oC
    -40oC~180oC
    -40oC~200oC
  • Control Mode
  • Feedback PID + Our special dynamic control calculation, PLC controller
  • Temp Control
  • Process temp. control and jacket temp. control model
  • Temp Difference
  • Set or control the temperature difference between jacket oil and raw material process
  • Program Editor
  • 10 programs, each program can edit 42 steps
  • Communication Protocol
  • MODBUS RTU Protocol,RS485 interface
  • Material Temp Feedback
  • PT100 OR 4~20mA or communication(normal: PT100)
  • Temp Feedback
  • The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
  • Medium Temp Acccuracy
  • ±0.5oC
  • Material Temp Accuracy
  • ±1oC
  • Expansion Valve
  • Emerson thermal expansion valve/DANFOSS thermal expansion valve
  • Evaporator
  • DANFOSS/KAORI Plate heat exchanger
  • Operation Panel
  • 7-inch touch screen,show temp curve\EXCEL data output
  • Safety Protection
  • Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
  • Closed Circulation System
  • The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
  • Refrigerant
  • R404A/R507C, optional: R448A

MANUFACTURED BY

CONTACT US

We automate and customize based on your specific requirement. Connect with us.

Phone +91 9618595672
Email info@e3techsys.com
Head Office 30-15-189, 4th Floor, Fonta Plaza,
Dabagardens, Visakhapatnam - 530020
Western Region No.602, 6th Floor, World Trade Centre
Sayajiganj, Vadodara-390005
Southern Region 111/314 C (X/269), Gokulam , Ayani Road
Maradu, Kochi - 682304