HEATING COOLING MACHINE AVAILABLE FOR HIRE
ATEX, FLP MODELS AVAILABLE

Select your Model

Filter - ZLF Series & SR Series

SR Series - Secondary Heat Transfer

Download PDF
ModelSR-35N
SR-35NS
SR-35NH
SR-35NSH
SR-50N
SR-50NS
SR-50NH
SR-50NSH
SR-80N
SR-80NS
SR-80NH
SR-80NSH
SR-125N
SR-125NS
SR-125NH
SR-125NSH
SR-200N
SR-200NS
SR-200NH
SR-200NSH
Expansion tank100L200L280L390L500L
Heat exchanger area3.5m25m28m212.5m220m2
Electric heating function25 kW35 kW50 kW65 kW80 kW
Temperature accuracy±1oC±1oC±1oC±1oC±1oC
Circulation pump200 l/min 2.5 bar 250 l/min 2.5 bar 400 l/min 2.5 bar 500 l/min 2.5 bar 750 l/min 2.5 bar
Connection sizeDN-40DN-40DN-50 DN-65 DN-80
Dimension mm1000*1200*1750 1250*1250*2000 1500*1500*2050 2050*1450*2050 2050*1450*2050
Dimension EX mm/////
Power AC380V50HZ1.6 kW(max) 2.1 kW(max)2.5 kW(max)5.7 kW(max) 7.7 kW(max)
With H power
AC380V 50HZ
26.6 kW(max) 37.1 kW(max)52.5 kW(max) 70.7 kW(max) 87.7 kW(max)
Case materialSUS 304 SUS 304 SUS 304 SUS 304 SUS 304
  • Temp range℃
  • -120~ 250degree setting the max temp according to the supplier heating or cooling source) -40~135degree(The maximum temperature range can be operated by using glycol water formula.)
  • SR-N
  • A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank.
  • SR-NS
  • Besides SR- N function,add one set heater used to reduce high temp.
  • SR-NH
  • Besides SR- N function,add electrical heating function
  • SR-NSH
  • Besides SR- N functio,add one set heater used to reduce high temp and electrical heating function
  • Control mode
  • Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
  • Communication protocol
  • MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
  • Temp control selection
  • Material control temp
  • Temperature feedback
  • The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
  • Process temp. feedback
  • Material temp. feedback:PT100 or 4~20mA or communication given Temp.feedback:PT100
  • Input and display
  • 7-inch color touch screen,temperature graph display
  • Safety protection
  • Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
  • Perform valve piece
  • Electric proportional control valve, control signal 4~20mA.
  • Piping material
  • SUS304

MANUFACTURED BY

CONTACT US

We automate and customize based on your specific requirement. Connect with us.

Phone +91 9618595672
Email info@e3techsys.com
Head Office 30-15-189, 4th Floor, Fonta Plaza,
Dabagardens, Visakhapatnam - 530020
Western Region No.602, 6th Floor, World Trade Centre
Sayajiganj, Vadodara-390005
Southern Region 111/314 C (X/269), Gokulam , Ayani Road
Maradu, Kochi - 682304