HEATING COOLING MACHINE AVAILABLE FOR HIRE
ATEX, FLP MODELS AVAILABLE

Select your Model

Filter By Machine Type

SUNDI -25℃~200℃ For Two Reactors

Download PDF
ModelSUNDI-225W-2TNSUNDI-235W-2TN SUNDI-255W-2TN SUNDI-275W-2TNSUNDI-2A10W-2TN
Heating Power (kW)2.5*23.5*25.5*27.5*210*2
Cooling capacity at 200oC (kW)2.5*23.5*25.5*27.5*210*2
Cooling capacity at 100oC (kW)2.5*23.5*25.5*27.5*210*2
Cooling capacity at 20oC (kW)2.5*23.5*25.5*27.5*210*2
Cooling capacity at 0oC (kW)1.5*22.5*23.5*25*27.5*2
Cooling capacity at -20oC (kW)1*21.6*22.1*23*24*2
Circulation pump
max Floe(L/min)
20*235*235*250*250*2
Circulation pump
Pressure(bar)
1.52222
Connection sizeG3/4 G3/4 G3/4 G3/4 G1
Water-cooled type
W (AT 20℃)
1200L/H 1.5bar~4bar1400L/H 1.5bar~4bar1700L/H 1.5bar~4bar2100L/H 1.5bar~4bar2500L/H 1.5bar~4bar
Dimension cm55*95*170 55*95*170 70*100*175 70*100*175 80*120*185
Dimension(W) cm55*95*170 70*100*175 70*100*175 80*120*185 100*150*185
Isolated ex-proof
size cm
/////
Positive Pressure (W) cm/////
Weight kg240285345385480
Power MAX
380V 50HZ
220V 7.5kW 11.5kW 17kW23kW31kW
Optional size
  • Temp Range
  • -25oC~+200oC
  • Control Mode
  • Feedback PID + Our special dynamic control calculation, PLC controller
  • Temp Control
  • process temp. control and jacket temp. control model TWO GROUPS
  • Temp Difference
  • Set or control the temperature difference between jacket oil and raw material process TWO GROUPS
  • Program Editor
  • /
  • Communication Protocol
  • MODBUS RTU Protocol,RS485 interface
  • Material Temp Feedback
  • PT100 OR 4~20mA or communication(normal: PT100)
  • Temp Feedback
  • the temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)*2
  • Medium Temp Acccuracy
  • ±0.5oC
  • Material Temp Accuracy
  • ±1oC
  • Expansion Valve
  • Emerson thermal expansion valve/DANFOSS thermal expansion valve.
  • Evaporator
  • DANFOSS/KAORI Plate heat exchanger
  • Operation Panel
  • 7-inch touch screen,show temp curve\EXCEL data output
  • Safety Protection
  • Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
  • Closed Circulation System
  • The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
  • Refrigerant
  • R404A/R507C, optional: R448A

MANUFACTURED BY

CONTACT US

We automate and customize based on your specific requirement. Connect with us.

Phone +91 9618595672
Email info@e3techsys.com
Head Office 30-15-189, 4th Floor, Fonta Plaza,
Dabagardens, Visakhapatnam - 530020
Western Region No.602, 6th Floor, World Trade Centre
Sayajiganj, Vadodara-390005
Southern Region 111/314 C (X/269), Gokulam , Ayani Road
Maradu, Kochi - 682304