HEATING COOLING MACHINE AVAILABLE FOR HIRE
ATEX, FLP MODELS AVAILABLE

Select your Model

Filter By Machine Type

SUNDI -60℃~300℃

Download PDF
ModelSUNDI-655WV SUNDI-675WV SUNDI-6A10WV SUNDI-6A15WV SUNDI-6A25WV
Heating Power (kW)5.57.5101525
Cooling capacity at 300oC (kW)5.57.5101525
Cooling capacity at 100oC (kW)5.57.5101525
Cooling capacity at 20oC (kW)5.57.5101525
Cooling capacity at -20oC (kW)4.868.21225
Cooling capacity at -40oC (kW)2.33.14.87.818
Cooling capacity at -55oC (kW)0.750.91.52.86
Circulation pump
max Floe(L/min)
5050110110150
Circulation pump
Pressure(bar)
222.52.52.5
Connection sizeG3/4 G1G1G1DN32 PN10
Water-cooled type
W (AT 20℃)
1800L/H 1.5bar~4bar2100L/H 1.5bar~4bar3000L/H 1.5bar~4bar4000L/H 1.5bar~4bar8.5m³/H 1.5bar~4bar
Dimension cm55*95*170 55*95*170 70*100*175 80*120*185 100*150*185
Dimension(W) cm/////
Isolated ex-proof
size cm
/////
Positive Pressure (W) cm/////
Weight kg265305340380980
Power MAX
380V 50HZ
10kW14kW18kW26kW40kW
Optional size
  • Temp Range
  • -60oC~+300oC (system add pressure 3BAR)
  • Control Mode
  • Feedback PID + Our special dynamic control calculation, PLC controller
  • Temp Control
  • Process temp control and jacket temp control model
  • Temp Difference
  • Set or control the temperature difference between jacket oil and raw material process
  • Program Editor
  • 10 programs, each program can edit 42 steps.
  • Communication Protocol
  • MODBUS RTU Protocol, RS485 interface
  • Material Temp Feedback
  • PT100 OR 4~20mA or communication(normal: PT100)
  • Temp Feedback
  • The temp of three points: the inlet and outlet of equipment, reactor material temp(external temp sensor)
  • Medium Temp Acccuracy
  • ±0.5oC
  • Material Temp Accuracy
  • ±1oC
  • Expansion Valve
  • Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
  • Evaporator
  • DANFOSS/KAORI Plate heat exchanger
  • Operation Panel
  • 7-inch touch screen,show temp curve\EXCEL data output
  • Safety Protection
  • Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
  • Closed Circulation System
  • The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
  • Refrigerant
  • R404A/R23 mixture,optional: R125/R23 mixture

MANUFACTURED BY

CONTACT US

We automate and customize based on your specific requirement. Connect with us.

Phone +91 9618595672
Email info@e3techsys.com
Head Office 30-15-189, 4th Floor, Fonta Plaza,
Dabagardens, Visakhapatnam - 530020
Western Region No.602, 6th Floor, World Trade Centre
Sayajiganj, Vadodara-390005
Southern Region 111/314 C (X/269), Gokulam , Ayani Road
Maradu, Kochi - 682304