HEATING COOLING MACHINE AVAILABLE FOR HIRE
ATEX, FLP MODELS AVAILABLE

Select your Model

Filter By Machine Type

SUNDI -80℃~250℃

Download PDF
ModelSUNDI-825WSUNDI-835WSUNDI-855WSUNDI-875WSUNDI-8A10WSUNDI-8A15WSUNDI-8A25WSUNDI-8A38WSUNDI-8A60WSUNDI-8A80W
Heating Power (kW)2.53.55.57.5101525386080
Cooling capacity at 250oC (kW)2.53.55.57.5101525386080
Cooling capacity at 0oC (kW)2.53.55.57.5101525386080
Cooling capacity at -40oC (kW)1.82.63.35.86.41120314865
Cooling capacity at -60oC (kW)11.41.633.55.810162332
Cooling capacity at -75oC (kW)0.30.420.71.31.52.4581116
Cooling capacity at 100oC (kW)2.53.55.57.5101525386080
Circulation pump
max Floe(L/min)
20355050110110150200400400
Circulation pump
Pressure(bar)
22222.52.52.52.52.52.5
Connection sizeG1/2 G3/4 G3/4 G1G1G1DN32 PN10 DN40 PN10DN50 PN10DN50 PN10
Water-cooled type
W (AT 20℃)
900L/H 1200L/H 1800L/H 2300L/H 3200L/H 4500L/H 8m³/H 12m³/H 20m³/H 30m³/H
Dimension cm55*68*145 55*68*145 55*95 *17055*95 *17070*100 *175100*95*185 150*100*185 205*145 *205245*145 *225300*160 *225
Dimension(W) cm//////////
Isolated ex-proof
size cm
//////////
Positive Pressure (W) cm//////////
Weight kg2402853455006009501300155022002850
Power MAX
380V 50HZ
6.5kW 10kW 13kW19kW 25kW 37kW50kW 71kW 110kW 150kW
Optional size
  • Temp Range
  • -80oC~+250oC
  • Control Mode
  • Feedback PID + Our special dynamic control calculation, PLC controller
  • Temp Control
  • Process temp. control and jacket temp. control model
  • Temp Difference
  • Set or control the temperature difference between jacket oil and raw material process
  • Program Editor
  • 10 programs, each program can edit 42 steps.
  • Communication Protocol
  • MODBUS RTU Protocol, RS485 interface
  • Material Temp Feedback
  • PT100 OR 4~20mA or communication(normal: PT100)
  • Temp Feedback
  • The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)
  • Medium Temp Acccuracy
  • ±0.5oC /±1oC
  • Material Temp Accuracy
  • ±1oC
  • Expansion Valve
  • Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
  • Evaporator
  • DANFOSS/KAORI Plate heat exchanger
  • Operation Panel
  • 7-inch touch screen,show temp curve\EXCEL data output
  • Safety Protection
  • Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
  • Closed Circulation System
  • The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
  • Refrigerant
  • R404A/R23/R14 mixture,optional: R125/R23/R14 mixture

MANUFACTURED BY

CONTACT US

We automate and customize based on your specific requirement. Connect with us.

Phone +91 9618595672
Email info@e3techsys.com
Head Office 30-15-189, 4th Floor, Fonta Plaza,
Dabagardens, Visakhapatnam - 530020
Western Region No.602, 6th Floor, World Trade Centre
Sayajiganj, Vadodara-390005
Southern Region 111/314 C (X/269), Gokulam , Ayani Road
Maradu, Kochi - 682304