HEATING COOLING MACHINE AVAILABLE FOR HIRE
ATEX, FLP MODELS AVAILABLE

Select your Model

Filter - ZLF Series & SR Series

ZLF Series - Direct Flow Control

Download PDF
ModelZLF-35N
ZLF-35NS
ZLF-35NH
ZLF-35NSH
ZLF-50N
ZLF-50NS
ZLF-50NH
ZLF-50NSH
ZLF-80N
ZLF-80NS
ZLF-80NH
ZLF-80NSH
ZLF-125N
ZLF-125NS
ZLF-125NH
ZLF-125NSH
ZLF-200N
ZLF-200NS
ZLF-200NH
ZLF-200NSH
Expansion tank// ///
Heat exchanger area3.5m25m28m212.5m2 20m2
Electric heating function25 kW35 kW50 kW65 kW80 kW
Temperature accuracy±1oC±1oC±1oC±1oC±1oC
Circulation pump150 l/min 2.5 bar200 l/min 2.5 bar 400 l/min 2.5 bar 500 l/min 2.5 bar 750 l/min 2.5 bar
Connection sizeDN-40DN-40DN-50 DN-65 DN-80
Dimension mm1000*950*1750 1250*1000*2000 1500*1250*2050 2050*1450*20502050*1450*2050
Dimension EX mm1000*1200*17501250*1250*20001500*1500*20502050*1450*20502050*1450*2050
Power AC380V50HZ1.6 kW(max)2.1 kW(max)2.5 kW(max)5.7 kW(max)7.7 kW(max)
With H power
AC380V 50HZ
26.6 kW(max) 37.1 kW(max)52.5 kW(max)70.7 kW(max)87.7 kW(max)
Case materialSUS 304SUS 304SUS 304SUS 304 SUS 304
  • Temp range℃
  • -45~ 250degree (setting the max temp according to the supplier heating or cooling source) -40~135degree(The maximum temperature range can be operated by using glycol water formula.)
  • ZLF- N
  • The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled.
  • ZLF- NS
  • Besides ZLF- N function, add one set heater used to reduce high temp.
  • ZLF- NH
  • Besides ZLF- N function,add electrical heating function
  • ZLF- NSH
  • Besides ZLF- N function, add one set heater used to reduce high temp and electrical heating function
  • Control mode
  • Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
  • Communication protocol
  • MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
  • Temp control selection
  • Process temp control
  • Temperature feedback
  • The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
  • Process temp. feedback
  • Raw material process feedback:PT100 or 4~20mA or communication given Temp. feedback:PT100
  • Input and display
  • 7-inch color touch screen,temperature graph display
  • Safety protection
  • Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
  • Perform valve piece
  • Electric proportional control valve, control signal 4~20mA.
  • Piping material
  • SUS304

MANUFACTURED BY

CONTACT US

We automate and customize based on your specific requirement. Connect with us.

Phone +91 9618595672
Email info@e3techsys.com
Head Office 30-15-189, 4th Floor, Fonta Plaza,
Dabagardens, Visakhapatnam - 530020
Western Region No.602, 6th Floor, World Trade Centre
Sayajiganj, Vadodara-390005
Southern Region 111/314 C (X/269), Gokulam , Ayani Road
Maradu, Kochi - 682304